High quality and availablity of energy adapted to suit specific critical needs
Covering a vast range of applications.
Applied to a variety of mobile applications such as commercial, emergency and recreational vehicles, marine vessels, construction and military equipment
Extremely low return noise and no disturbance to talking quality.
Special charging system design for better protection of battery life.
Short circuit, overload, overload, over voltage and low battery protection.
With standard on-line structure (three ports)and can be used as UPS. Specification
Compatible with generators and suitable for harsh environment where power voltage is extremely unstable.
RS232 port, smart power management software, automatic file saving and shutting down at power abnormalities.
Use-friendly interface, LED simulative display, LCD digital display and computer screen display of inverter operation status.
MODEL | 115V Models | 230V Models | |
OUTPUT | |||
Power Levels crated at | 1000W,1500W,2000W,3000W,4000W | 1000W,1500W,2000W,3000W,4000W | |
Output Voltage | 120V(+/-10%) | 220V(+/-10%) | |
Voltage Waveform | Pure Sine wave | ||
Crest Factor | 3:1 | ||
Output Frequency | Auto Select for 50/60Hz | ||
(Synchronized to Mains) | 47Hz ~ 55Hz for 50Hz nominal | ||
56Hz ~ 65Hz for 60Hz nominal | |||
Regulation (Nominal) | ±10% typical of nominal voltage | ||
Regulation(Battery mode | ±3% of selected output voltage | ||
Transfer time | Blackout 3ms typical | ||
Brownout 1ms typical | |||
Battery mode to Normal mode:1ms typical | |||
Over current protection | Over load alarm level 100% ~ 120% | ||
Over load shutdown level 120% ~ 190% | |||
INPUT | |||
Nominal Voltage | 120V | 220V | |
Input Frequency | 47Hz ~ 65Hz, 50/60Hz auto-sensing | ||
Efficiency (Normal mode) | 97% | ||
Noise Filtering | Full time EMI/RFI filtering | ||
Voltage Range | 75V ~ 155V | 145V ~ 280V | |
AVR Range(2 Bucks, 2 Boosts) | Enhanced Buck: +28% of selected nominal voltage | ||
Buck mode: +10% of selected nominal voltage | |||
Boost mode: -10% of selected nominal voltage | |||
Enhanced Boost: -25% of selected nominal voltage | |||
Surge Protection | 424 Joules | ||
BATTERY | |||
Battery type | Lead-Acid 50Ah to 500Ah (Recommended) | Lead-Acid 50Ah to 500Ah (Recommended) | |
Voltage | 1000W:12/24VDC; 1500W-2000W:24/48VDC; 3000W-4000W:48VDC | ||
Typical backup time | No Limit | ||
Charging method | Quick charging when battery is not fully charged, | ||
trickle charging when battery is 90% fully charged. | |||
Maximum charging current | 15-25amp(MAX) | ||
Average charging | Quick charging mode:14V maximum. | ||
voltage for each battery | Trickle charging mode:13.5V (adjustable with the remote set-up software) | ||
Protection | Over current protection & Over charging voltage protection (SCR control) | ||
Thermal protection (CPU control) | |||
When temperature inside the unit is over50 °C, charger willstop charging for 2 minutes followed by an 2 minutes charging. The cycle will be repeat | |||
Monitoring | Smart monitoring & warning for failed battery or open-circuit battery. | ||
Auto-detection each time when power on or every 6 days. | |||
SOLAR CHARGER(OPTIONAL) | |||
Rating voltage | 12V / 24V / 48V | 12V / 24V / 48V | |
DC input range | 12V model : 12 ~ 21Vdc | ||
24V model : 24 ~ 42Vdc | |||
48V model : 48 ~ 84Vdc | |||
Charging method | Constant voltage with current limiting by PWM control | ||
Charging voltage | 12V model :13.5Vdc | ||
24V model : 27.0Vdc | |||
48V model : 54.0Vdc | |||
Power rating | 12V model : 13.5Vdc @ 37A | ||
24V model : 27.0Vdc @ 37A | |||
48V model : 54Vdc @ 18.5A | |||
Protection | DC input polarity protection, DC input short circuit protection( when battery is | ||
connected), DC output over current protection | |||
COMMUNICATIONS & MANAGEMENT | |||
Standard Interface port | UPSilon2000 compatible; optional for RS232 . | ||
Optional Interface part | RJ45 (Surge protection), DB9, | ||
Control panel | LCD or LED Selectable | ||
Audible alarm | Alarm on battery:Low battery & Battery over voltage | ||
Alarm on abnormal operation:Over load, Short-circuit, & Over heat | |||
Green mode function | 1% to 14% of full load (adjustable by using the remote set-up software) | ||
(Auto-shut-off in blackout) | The default setting is OFF. | ||
Cooling fan control | Auto on / off, controlled by temperature & operation mode | ||
ENVIRONMENTAL AND SAFETY | |||
Operating Temperature | Up to 1500 meters:0 °Cto 40°C (32°F to 104°F) | ||
Transit/storage Temp. | 15°C below zero to 55°C (5°F to 131°F) | ||
Relative Humidity | 5 - 95% non condensing | ||
Operating Altitude | 0 ~ 3000 meters | ||
Quality control system | ISO 9001:2000, ISO 14002-2004 | ||
PHYSICAL | |||
Appearance | product size(mm) | 1000W-1500W:452×192×338MM | |
2000W-4000W:500×260×455MM | |||
Weight(Kg) | 1KW:14.0kg;1.5kw:25.0kg;2kw:28.0kg:3kw:30.0kg;4kw:35.0kg | ||
Carton Gross Weight | 1KW:15.0kg;1.5kw:27.0kg; 2kw:31.0kg; 3kw:36.0kg;4kw:41.0kg |