Pure copper transformerinside and pure copper DC terninal port outside
Durable construction for long life under extreme environmental conditions
Applied in the field of industrial process controls, battery charging requirements, personal computers, telecommunications and others.
Manual Main Features:Built-in starting control circuits for two- and three-wire generator starting systems
Simplified controls with a snap-on cover that protects settings from being accidentally changed
Better thermal performance allows full output power to 50°C (122°F) without de-rating
High surge capacity starts more difficult loads and handles overload conditions reliably
Durable powder coated, corrosion resistant steel chassis
70-amp automatic three-stage battery charger (bulk, absorption, and float) and battery equalization with remote temperature sensor for increased performance
MODEL | 230V Models | ||
OUTPUT | |||
Power Levels crated at nominal inputs | 1KW;2KW;3KW | ||
Output Voltage | 220V/230V/240V Selectable | ||
Voltage Waveform | Pure Sine wave | ||
Crest Factor | 3:'1 | ||
Output Frequency | Auto Select for 50/60Hz,47Hz ~55Hz for 50Hz nominal,56Hz ~ 65Hz for 60Hz nominal | ||
(Synchronized to Mains) | |||
efficienly(DC mode) | >80% | ||
Surge Rating | 3000VA / 6000VA / 9000VA | ||
Capable of motor | 1kw/2kw: 1HP 3KW:2HP | ||
Transfer time | 10ms typical | ||
protection | Over load protection, battery over voltage & under voltage protection | ||
Oover temperature protection | |||
short circuit protection | |||
INPUT | |||
Nominal Voltage | 220V/230V/240V Selectable | ||
Input Frequency | 40Hz ~ 80Hz, 50/60Hz auto-sensing | ||
Efficiency (line mode) | >95% | ||
Noise Filtering | Full time EMI/RFI filtering | ||
Voltage Range | 155Vac-265Vac | ||
Charge current | 65A max. | ||
Inverter main features | huge charge current | ||
pure copper transformer | |||
pure sine wave | |||
supports inductive loads | |||
Surge Protection | 1KW-3KW:430 Joules | ||
BATTERY | |||
Battery type | Lead-Acid 50Ah~500Ah (Recommended) | Lead-Acid 50Ah~500Ah (Recommended) | |
DC Voltage | 1KW:12Vdc | 2KW:12Vdc | |
2KW:24Vdc | 3KW:12Vdc | ||
3KW:24Vdc | 3KW: 48Vdc | ||
Typical backup time | up to external battery | ||
Charging method | battery charger (bulk, absorption, and float) | ||
charge current is ajustable 25% 50% 75% 100% (optional) | |||
Maximum charging current | 1000W 12V:35A | 2000W 12V:65A | |
2000W 24V:35A | 3000W 12V:65A | ||
3000W 24V:45A | 3000W 48V:25A | ||
Average charging | Quick charging mode:15.7V-54V maximum. | ||
voltage for each battery | Trickle charging mode:13.5V -52V | ||
Protection | Over current protection | ||
Over charging voltage protection | |||
When temperature inside the unit is over 45°C ,charger will stop charging for 2 minutes followed by an 2 minutes charging. The cycle will be repeate | |||
Monitoring | RS232 communication port | ||
remote control cable 10 meters | |||
SOLAR CHARGER | |||
Rating voltage | 12V / 24V / 48V | ||
DC input range | 12V model : 12 ~ 21Vdc;24V model : 24 ~ 42Vdc;48V model : 48 ~ 84Vdc | ||
Charging method | Constant voltage with current limiting by PWM control | ||
Charging voltage | 12V model:13.5Vdc;24V model: 27.0Vdc;48V model: 54.0Vdc | ||
Power rating | 12V model : 1000W/2000W (13.5Vdc @ 37A) | ||
24V model : 1000W/2000W (27.0Vdc @ 37A) | |||
48V model : 3KW/4KW/5KW/6KW (54Vdc @ 18.5A) | |||
Protection | DC input polarity protection, DC input short circuit protection. | ||
(when battery is connected), DC output over current protection. | |||
COMMUNICATIONS & MANAGEMENT | |||
Control panel | LCD&LED indicators | ||
Audible alarm | Alarm on battery:Low battery & Battery over voltage | ||
Alarm on abnormal operation:Over load, Short-circuit, & Over heat | |||
Green mode function | 1% to 14% of full load | ||
(Auto-shut-off in blackout) | The default setting is OFF. | ||
Cooling fan control | Auto on / off, controlled by temperature & operation mode | ||
ENVORMENT AND SAFETY | |||
Operating Temperature | Up to 1500 meters:0°C to 40°C (32°Fto 104°F) | ||
Transit/storage Temp. | -15°C to 55(5°F to 131°F) | ||
Relative Humidity | 5 - 95% non condensing | ||
Operating Altitude | 0 ~ 3000 meters | ||
Quality control system | ISO 9001 | ||
PHYSICAL | |||
Appearance | Size(mm)LxWxH | 570*315*300mm | |
Weight(Kg) | 1000W/19kg ;2000W/24kg ;3000W/28kg |