Applied in the field of industrial process controls, battery charging requirements, personal computers, telecommunications, graphics displays, plating and gold recovery industries and wherever required in the commercial, telecoms, mining or industrial markets.Commercial Solar, Recreational Vehicles, Mobile Office, Industrial Wind, Boats, Truck, & RV Residential Solar, Emergency Vehicles, Residential Wind, Fleet & Utility Vehicles, Camping & Outdoors, Renewable Newsletter.
Manual Main Features:70-amp automatic three-stage battery charger (bulk, absorption, and float) and battery equalization with remote temperature sensor for increased performance
Pure copper transformerinside and pure copper DC terninal port outsideDurable construction for long life under extreme environmental conditions
MODEL | 230VModels | ||
OUTPUT | |||
Power Levels crated at nominal inputs | 4KW;5KW,6KW | ||
Output Voltage | 220V/230V/240V Selectable | ||
Voltage Waveform | Pure Sine wave | ||
Crest Factor | 3:'1 | ||
Output Frequency | Auto Select for 50/60Hz,47Hz ~55Hz for 50Hz nominal,56Hz ~ 65Hz for 60Hz nominal | ||
(Synchronized to Mains) | |||
Regulation (Nominal) | ±20% typical of nominal voltage | ||
Regulation | ±3% of selected output voltage (adjustable with the | ||
(Battery mode) | remote set-up software) | ||
Transfer time | 10 ms | ||
protection | Over load protection | ||
Over current protection | |||
Over temperature protection | |||
INPUT | |||
Nominal Voltage | 220V/230V/240V Selectable | ||
Input Frequency | 40-80Hz, 50/60Hz auto-sensing | ||
Efficiency (line mode) | 95% | ||
Noise Filtering | Full time EMI/RFI filtering | ||
Max bypass overload current | 40A | ||
Voltage Range | 155V ~ 265V | ||
Product Features | huge charge current | ||
pure copper transformer | |||
pure sine wave | |||
supports inductive loads | |||
Charge current | current is adjustable 25% 50% 75% 100% | ||
BATTERY | |||
Battery type | Lead-Acid 50Ah~500Ah (Recommended) | Lead-Acid 50Ah~500Ah (Recommended) | |
4KW/5KW/6KW: 24Vdc /48Vdc optional | |||
Typical backup time | up to external battery | ||
Charging method | battery charger ( bulk, absorption, and float) | ||
over charge protection | |||
Maximum charging current | 4000W 24V: 65A5000W/24V: 65A | ||
5000W 48V: 40A | 6000W 48V: 50A | ||
Average charging | Quick charging mode:15.7V-54V maximum. | ||
voltage for each battery | Trickle charging mode:13.5V -52V | ||
Protection | battery over-voltage & under voltage protection | ||
over temperature protection | |||
overload & short circuit protection | |||
Monitoring | RS232 | ||
remote control | |||
SOLAR CHARGER | |||
Rating voltage | 24V / 48V | ||
DC input range | 24V model : 24 ~ 42Vdc;48V model : 48 ~ 84Vdc | ||
Charging method | Constant voltage with current limiting by PWM control | ||
Charging voltage | 24V model: 27.0Vdc;48V model: 54.0Vdc | ||
power rating | 48V model :4KW/5KW/6KW (54Vdc @ 18.5A) | ||
Protection | DC input polarity protection, DC input short circuit protection | ||
(when battery is connected), DC output over current protection | |||
COMMUNICATIONS & MANAGEMENT | |||
Control panel | LCDdisplay & LED indicators | ||
Audible alarm | Alarm on battery:Low battery & Battery over voltage | ||
Alarm on abnormal operation:Over load, Short-circuit, & Over heat | |||
Green mode function | 1% to 14% of full load | ||
(Auto-shut-off in blackout) | The default setting is OFF. | ||
Cooling fan control | Auto on / off, controlled by temperature & operation mode | ||
ENVORMENT AND SAFETY | |||
Operating Temperature | Up to 1500 meters:0°C to 40°C (32°Fto 104°F) | ||
Transit/storage Temp. | -15°C to 55(5°F to 131°F) | ||
Relative Humidity | 5 - 95% non condensing | ||
Operating Altitude | 0 ~ 3000 meters | ||
Quality control system | ISO 9001 | ||
PHYSICAL | |||
Appearance | Size(mm)LxWxH | 755*319*288 | |
Weight(Kg) | 4000W/38kg ;5000W/49kg ;6000W/49kg |