Applied in the field of industrial process controls, battery charging requirements, solar system.Camping & Outdoors, Renewable Newsletter,
Manual Main Features:•12v/24vdc input optional
•Max. AC charger current 70A(Optional)
•Inbuilt pure copper transformer
•Pure sine wave output
•LCD status display
•MPPT solar controller 20A~40A
•50Hz/60Hz automatic
•RS232 with free CD(optional)
•Battery priority function
Specifications:Model | PV1012C | PV1024C | PV2012C | PV2024C | PV3012C | PV3024C |
Rated Output Power(W) | 1000 | 2000 | 3000 | |||
Line mode specifications | ||||||
Input Voltage | 12V | 24V | 12V | 24V | 12V | 24V |
Input Frequency | 50Hz@40-80Hz/60Hz@40-80Hz | |||||
Output Voltage Waveform | Pure Sine Wave | |||||
Output Short Circuit Protection | Current limit (Fault after 10s) | |||||
Inverter Mode Specifications | ||||||
Output Voltage Waveform | Pure Sine Wave | |||||
Power Factor | 1 | |||||
Output Voltage (V) | 110Vac/120Vac/220Vac/230Vac ±10% | |||||
Output Frequency (Hz) | 60Hz ± 0.3Hz / 50Hz ± 0.3Hz | |||||
Auto Tracking Main Frequency | Yes (Following main first connection);50Hz @40-80Hz;60Hz @40-80Hz | |||||
Output Voltage Regulation | ±10% rms | |||||
Efficiency | >80% | |||||
Over-Load Protection | (110%<load<125%) ±10%: Fault (shutdown output) after 15 minutes; (125%<load<150%) ±10%: Fault (shutdown output) after 60s; Load>150 ±10%: Fault (shutdown output) after 20s | |||||
Surge Rating | 3000VA | 6000VA | 9000VA | |||
Capable Of Starting Electric Motor | 1HP | 1HP | 2HP | |||
Inverter Breaker Size | 10A | 30A | ||||
DC Input Voltage | 12V | 24V | 12V | 24V | 12V | 24V |
Min DC Start Voltage | 11V/22V | |||||
Low Battery Alarm | 10.5Vdc ± 0.3Vdc for 12V battery; 21.0Vdc ± 0.6Vdc for 24V battery | |||||
Low DC Input Shut-Down | 10.0Vdc ± 0.3Vdc for 12V battery; 20.0Vdc ± 0.6Vdc for 24V battery | |||||
High DC Input Alarm & Fault | 16.0Vdc ± 0.3Vdc for 12V battery; 32.0Vdc ± 0.6Vdc for 24V battery | |||||
High DC Input Recovery | 15.5Vdc ± 0.3Vdc for 12V battery; 31.0Vdc ± 0.6Vdc for 24V battery | |||||
Power Saver | Load ≤ 25W | |||||
Charger Mode Specifications | ||||||
Input Voltage | 110Vac/120Vac/220Vac/230Vac | |||||
Input Voltage Range | 96~127Vac/ 155~265Vac | |||||
Output Voltage | 110Vac/120Vac/220Vac/230Vac ±10% | |||||
Charge Current | ||||||
Charge Current Regulation | Charge Current Adjustable: 25%, 50%, 75%, 100%. (Optional) | |||||
Battery Initial Voltage | 0-15.7Vdc / 31.4Vdc (can operate with 0V battery) | |||||
Charger Short Circuit Protection | Circuit breaker | |||||
Over Charge Protection | Bat. V ≥15.7Vdc/ 31.4Vdc , beeps 0.5s every 1s & fault after 60s | |||||
General Specifications | ||||||
Certification | CE / Soncap / ISO9001 | |||||
Operating Temperature Range | 0°Cto 40°C | |||||
Storage Temperature | -15°C to 60°C | |||||
Operation Humidity | 5% to 95% | |||||
Audible Noise | 60dB max | |||||
Cooling | Forced air, variable speed fan | |||||
Size | 1012C / 1024C / 2012C / 2024C / 3012C / 3024C: 460x260x185MM | |||||
Gross Weight | 21KG | 26KG | 29.8KG |
MPPT solar controller function | ||
Rated voltage | 12/24V DC | |
Rated charge current | 40A | |
Load current | 15A | |
Input voltage range | 15-55V DC | |
Max. PV open circuit array voltage | 55V DC | |
Typical idle consumption | At idle< 10mA | |
Overload protection(DC load) | 2.0*Inom>5s; 1.5*Inom>20s; 1.25*Inom temperature controlled | |
Bulk charge | 14.6V(default) | 29.2V(default) |
Floating charge | 13.4V(default) | 26.8V(default) |
Equalization charge | 14.0V(default) | 28.0V(default) |
Over charge disconnection | 14.8V | 29.6V |
Over charge recovery | 13.6V | 27.2V |
Over discharge disconnection | 10.8V(default) | 21.6V(default) |
Over discharge reconnection | 12.3V | 24.6V |
Temperature compensation | 13.2mV/C | 26.4mV/C |
Lead acid battery settings | Adjustable | |
NiCad battery settings | Adjustable | |
Load control mode | 1.Low Voltage Reconnect(LVR):Adjustable;2.Low Voltage Disconnect(LVD):Automatic disconnection;3.Reconnection:Includes warning flash before disconnect and reconnection | |
Low voltage reconnect | 12.0-14.0Vdc | 24.0-28.0Vdc |
low voltage disconnet | 10.5-12.5Vdc | 21.0-25.0Vdc |
Ambient temperature | 0 to 40°C (full load); 40-60°C (de-rating) | |
Altitude | Operating5000m, Non-Operating 16000m | |
Protection class | IP21 | |
Battery temperature sensor | BTS-optional remote battery temperature sensor for increased charging precision | |
Terminal size(fine/single wire) | #8 AWG |