- Line interactive UPS is the perfect protection partners for computer,
- Workstations and POS system.
- Widely used in municipal, bank, postal coupons, communication transportation,radio and television, and power
- Public hospital, industrial control, defense, etc,
- Computer room, data center, and the server for electric power
- Environmental requirements of network equipments, strict communication and information.
Fully digitized microprocessor controlled .
LCD series CPU control guarantees high reliability
Lightning and surge protection.
Cold start function (DC power on).
Equipped with AVR to stabilize output voltage wide input voltage range
Generator Compatible
Auto charging even though the UPS is off
Smart RS232 or USB communication interfaces
Sealed lead-acid, maintenance free battery
Battery low voltage, overload & short circuit protection.
Advanced automatic constant charging circuit, prolongs battery life
Automatic buck and boost AVR function, wide input voltage 155-280VAC
Lead-Acid, maintenance free battery inside, provides strong power to users.
MODEL | EW2110 500 | EW2110 600 | EW2110 650 | EW2110 800 | EW2110 1000 |
CAPACITY | 500VA /300W | 600VA /360W | 650VA /390W | 800VA /480W | 1000VA /600W |
INPUT | |||||
Phase | single | ||||
Voltage | 110/120 VAC or 220/230/240 VAC | ||||
Voltage Range | 81-145 VAC / 162-290 VAC | ||||
Frequency Range | 60/50 Hz ±1%(auto sensing) | ||||
OUTPUT | |||||
Phase | single | ||||
Voltage (Batt. Mode) | 115VAC or 230 VAC | ||||
Frequency Range (Batt. Mode) | 60 Hz or 50 Hz ±1 Hz | ||||
Transfer Time | Typical 2-6 ms, 10ms max. | ||||
Overload Capability | 110% for 5 min, 120% immediate shutdown | ||||
Waveform (Batt. Mode) | Modified SineWave | ||||
BATTERY | |||||
Battery Type & Number | 12 V/7 AH x 1 | 12 V/7 AH x 1 | 12 V/7 AH x 1 | 12 V/9 AH x 1 | 12 V/7 AH x 2 |
Typical Recharge Time | 8 hours to 90% after complete discharge | ||||
Backup Time(at a 1 PC load with 15 monitor) | 10 minutes | 9 minutes | 8 minutes | 9minutes | 13 minutes |
INDICATORS | |||||
LCD Indicator with Blue Back Light | The LCD will self turn on when the UPS is functioning including in, off, charging mode and fault mode | ||||
PROTECTION | |||||
Full Protection | Overload, discharge, and overcharge protection | ||||
TRANSFER TIME | |||||
Typical | 2-6ms | ||||
ALARM | |||||
Battery Mode | Sounding every 10 seconds | ||||
Low Battery | Sounding every second | ||||
Overload | Sounding every 0.5 second | ||||
Battery Replacement Alarm | Sounding every 2 seconds | ||||
Fault | Continuously sounding | ||||
PHYSICAL | |||||
Dimension, D X W X H (mm) | 330 x 100 x 140 | ||||
Net Weight (kgs) | 5.0 | 6.0 | 6.5 | 8.5 | 10.5 |
OPERATING ENVIRONMENT | |||||
Humidity | 0-90 % RH @ 0- 40°C (non-condensing) | ||||
Noise Level | Less than 40dB | ||||
MANAGEMENT | |||||
Optional USB/RS-232 Port | Supports Windows® 98/2000/2003/XP/Vista/2008, Windows® 7, Linux, and MAC |