- High quality and availablity of energy adapted to suit specific critical needs,
- Covering a vast range of applications.
- Silent running
-Can be used to protect other senstiive electronic devices including Home Cinemas, DVD players, Satellite and Digital Terrestrial receivers.
Maximum power protection with PowerShield UPSmonitoring and shutdown software available for free download from our website www.mustups.com.
Suitable for installation on PCs running Windows Vista, 2003, XP, 2000, Me, 98; Linux, Mac OSX and the Sun Solaris operating system.
Accurate pure sine wave output ;strong capacity of different load.
Advanced performance due to the CPU control.
Wide range of power input and accurate output AVR.
Perfect protection for overload ,short circuit ,over-voltage ,low-voltage and over-heating etc.
Adapt to various of power net well ,compatible with generator
Front panel LCD display providing status, load and battery information and LEDs (standard version).
Compact dimensions and ergonomic design: it can be placed on a desk top or other convenient location, with easy to access connections and informative front panel.
UPS start automatically when the main power recover(optional).
Intelligent battery management.
MODEL | EW2150500M | EW2150650M | EW2150800M | EW2150 1000M | EW2150 1500M |
CAPACITY | 500VA/350W | 650VA/455 W | 800VA/560W | 1000VA/700W | 1500VA/1050W |
INPUT | |||||
Phase | Single | ||||
Voltage | 100/110/120/127/220/230(± 25%) VAC | ||||
Voltage Range | 81-145VAC/145-290VAC | ||||
Frequency Range | 60/50 ± 1% Hz (auto sensing) | ||||
OUTPUT | |||||
Phase | Single | ||||
Voltage (Batt. Mode) | 115VAC or 230 VAC | ||||
Frequency Range (Batt. Mode) | 60 Hz or 50 Hz ±1 Hz | ||||
Transfer Time | Typical 2-6 ms, 10ms max. | ||||
Waveform (Batt. Mode) | Sine Wave | ||||
BATTERY | |||||
Battery Type & Number | 12V/7AHx1 | 12V/7AHx1 | 12V/9AHx1 | 12V/7AHx2 | 12V/9AHx2 |
Typical Recharge Time | 8 hours to 90% after complete discharge | ||||
Backup Time(at a 1 PC load with 15 monitor) | 10 minutes | 9 minutes | 8 minutes | 13minutes | 16minutes |
Direct Voltage | 12V | 12V | 12V | 24V | 24V |
INDICATORS | |||||
LCD Indicator with Blue Back Light | The LCD will self turn on when the UPS is functioning including in, off, charging mode and fault mode | ||||
PROTECTION | |||||
Full Protection | Overload, discharge, and overcharge protection | ||||
ALARM | |||||
Battery Mode | Sounding every 10 seconds | ||||
Low Battery | Sounding every second | ||||
Overload | Sounding every 0.5 second | ||||
Battery Replacement Alarm | Sounding every 2 seconds | ||||
Fault | Continuously sounding | ||||
PHYSICAL | |||||
Dimension, D X W X H (mm) | 375*130*190 | ||||
Net Weight (kgs) | 6.5 | 6.5 | 8.0 | 11 | 9.0 |
OPERATING ENVIRONMENT | |||||
Humidity | 0-90 % RH @ 0- 40°C (non-condensing) | ||||
Noise Level | Less than 40dB | ||||
MANAGEMENT | |||||
Optional USB/RS-232 Port | Supports Windows® 98/2000/2003/XP/Vista/2008, Windows® 7, Linux, and MAC |