EH 9115 seriesprovides maximum protection for vital ‘mission-critical' networks, security applications (electro-medical) and industrial applications thanks to its outstanding mechanical and electrical design. The UPS has an extremely outstanding mechanical and electrical design: isolation transformer on the inverter, high short-circuit current and sinusoidal absorption with low THDi.
Manual Main Features:High accuracy and reliability due to the double DSP control system
low power consumption up to 94%
cold start directly and smart operation for users.
simple to install:capability to install the UPS into any distribution system (neutral not required on rectifier input)
capability of regulating the output voltage (to offset voltage drops down long cable runs)
built-in automatic and manual battery test feature, battery deep discharge protection and temperature compensating charger
back-feed protection: to avoid energy feeding back into the mains supply should a fault occur
reliable, filtered, stabilized and regulated sine wave output (double conversion on-line technology )with filters for atmospheric
disturbance suppression- high reliability, full microprocessor control with no-break static and manual bypasses,extremely high short-circuit
current to ensure compatibility with the most difficult transformer applications (lighting, drives and industrial processes) and an isolation
transformer on the inverter output- maximum reliability and power availability- high level diagnostics: event log with messages, status,
measurements and alarms - available from the built-in LCD in several languages
MODEL | EH9115-10K | EH9115-20K | EH9115-30K | EH9115-40K | EH9115-60K | EH9115-80K | |
CAPACITY | 10KVA/8KW | 20KVA/16KW | 30KVA/24KW | 40KVA/32KW | 60KVA/48KW | 80KVA/64KW | |
INPUT | |||||||
Voltage | 380/400/415 Vac±20%,3 Phase +N (3 phase and 4 wire) | ||||||
Input Frequency | 50/60 Hz ±10% | ||||||
Power Factor | >=0.95 | ||||||
phase | 3phase | ||||||
Input voltage protection | Electronic Input out of tolerant protection | ||||||
OUTPUT | |||||||
AC Voltage Regulation (Batt.Mode) | 380/400/415 Vac ±1%,3 Phase +N | ||||||
Voltage tolerant | (balanced load:+/- %1)(unbalanced:+/- %2)(full load:+/-%5) | ||||||
Voltage regulation time | After full load: 25 ms | ||||||
Frequency Range | 50Hz (60Hz special product) | ||||||
Frequency tolerant | (synchron:+/-%2) (free running:+/-%0,2) | ||||||
Efficiency (100% load) | >85% | >90% | |||||
Harmonic Distortion | <=3% THD (Linear Load),<=5% THD(Non Linear Load) | ||||||
Transfer Time | AC to DC | Zero | |||||
Inverter to Bypass | 4 ms (Typical) | ||||||
Waveform (Batt. Mode) | Pure Sine Wave | ||||||
Crest faktor | 3:1 | ||||||
BATTERY | |||||||
Battery Type & Numbers | Maintenance free lead-acid batteries / 12V x 32pcs | ||||||
charge current | 8A | ||||||
Battery Start | Yes, UPS can be started without AC source. | ||||||
Battery protection | Automatic circuit breaker | ||||||
Battery voltage protection | Electronic 3 level alarms | ||||||
OVERLOAD | |||||||
Overload protection | (>130-%150 load :60 seconds ) (>%150 load :30 seconds) | ||||||
Short circuit protection | Electronic protection | ||||||
Output voltage protection | Electronic out of tolerant protection | ||||||
PHYSICAL | |||||||
Dimension, D X W X H (mm) | 600x550x1250 | 780x700x1520 | |||||
Net Weight (kgs) | 200 | 270 | 330 | 360 | 430 | 500 | |
OPERATING ENVIRONMENT | |||||||
Humidity | 0% - 90% (NonLCCondensing) | ||||||
Temperature | 0 – 40°C | ||||||
Overtemperature protection | Electronic protection | ||||||
Noise Level | < 58 dBA (At 1 M) | < 63 dBA (At 1 M) | |||||
Altitude | <1000 M Above Sea Level | ||||||
LED,LCD,Buzzer | YES | ||||||
MANAGEMENT | |||||||
Remote Control | Dry contact, RS232 | ||||||
. All specifications mentioned above are subject to change without prior notice. |