高级搜索
相关搜索: Bluetooth, Virtual Reality, android, smart phone, mtk, smart watch, Keyboard, OPENBOX 查看更多
Low Frequency Online UPS TC10K-120K

Low Frequency Online UPS TC10K-120K

SKU编号: FS00018901
欢迎转载 功德无量
     
Key features:

��
Three phase in, three phase out


��
Microprocessor control

��
100% unbalance protection design

��
True on-line double conversion design providingallpowerprotection

��
Isolated output

��
Sine wave pulse width modulation

��
IGBT inverter design.

��
Wide Input voltage windows

��
Pure sine wave output less than 3% THD

��
Expandable battery run time

��
Generator compatible

��
Cold start

��
Load/Battery power meter display

��
Overload, on-line, battery status LED/LCD

��
Advanced Battery Management

��
Automatic charging in UPS off mode

��
Smart RS-232 communication port

��
Optional SNMP card
>
Technical Specifications

MODEL

TC10K

TC15K

TC20K

TC30K

TC40K

TC60K

TC80K

TC100K

TC120K

Capacity

10KVA

15KVA

20KVA

30KVA

40KVA

60KVA

80KVA

100KVA

120KVA

Power

8KW

12KW

16KW

24KW

32KW

48KW

64KW

80KW

96KW

Power Factor

0.8

Input

Phase

3 phase 4 wire and ground

Voltage Range

380V��20%(3 phase), phase voltage 220V

Frequency Range

45 �C 65Hz

Rectifier

3 phase 6 pulses, 12 pulses is optional

Output

Phase

3 phase 4 wire and ground

Wave form

Pure sine wave

Crest Factor

3:01

Rated voltage

380/400/415V optiona+ -1% for static load, 5% forfluctuant load

Phase voltage setting

200 - 244VAC, pls confirm when order

Transient response

+/-5%, 10ms

Frequency

50 / 60 Hz + / - 0.05%

Total harmonic distortion

< 3%(linear load, < 5%( nonlinear load)

Short circuit current

Short current for 0.1s (200% current)

Overload capacity

Overload 125% for 10 Mins, 125%-150% for 1min .automatically resume when load become normal

Battery

Battery

Maintenance free lead-acid cell

DC Voltage

384VDC

396VDC

Max Charge Current

6 -30A adjustable

Bypass

Type

Static state + manual maintenance bypass

Input Phase

3 phase 4 wire and ground

Input voltage range

15% - 25% (the front control panel selectable)

Transfer time

Inverter / bypass transfer switch time(Overload): 0ms inverter / bypass transfer switch time (fault inverter) 1ms

Efficiency

Whole unit

>80%

Inverter

91

91

92

92

93

93

95

95

95

Remote signaling

Dry contact (battery low, battery discharging, bypass/ fault); output 12Vdc/80mA,Optional parts

Communication interface

RS232 ( SNMP , modem optional )

Running temperature

0-40 degree Celsius

Relative Humidity

Less than 95% (without condensing)

Noise at 1 M

less than 60 dB

Degree of protection

IP20

Applicable Standards

EN50091-1-EMC EN50091-2liv.A

Product size(mm)

780*580*1170

1000*660*1450

1200*900*1820

product weight(Kg)

180

220

250

300

400

470

640

740

740

Package size(mm)

945*745*1395

1135*810*1755

1450*1110*1880

Package weight(Kg)

200

270

300

350

480

550

700

800

800