Recherche avancée
recherches apparentées: Bluetooth, Virtual Reality, android, smart phone, mtk, smart watch, Keyboard, OPENBOX Voir tous
Image de PCA 500-1500 LCD-Line UPS

PCA 500-1500 LCD-Line UPS

SKU: FS00019478
Reproduction is welcome and allowed for free circulation only.
     
Main Features

●With Stabilizer Function
●Wide Input Voltage Range
●Wide Input Frequency Range
●High/Low Voltage Protection, Overload/Short Protection
●Cool start computer even there isnt main power
●Automatic recharge even UPS is off
●Automatic restart
●Beeping Alarm on Battery, Battery Low and Overload
●Beeping Selection
●Intelligent Battery Management
●Intelligent LCD Display
●Smart RS232& RJ11& USBOption
●Compatibility with generators

Overview

Product

Requirements

Model 1

Model 2

Model 3

Model 4

Model 5

Model 6

Power (VA)

PCA-500

PCA-650

PCA-800

PCA-1000

PCA-1200

PCA-1500

Input

Voltage

80-150VAC / 145-290VAC ±5V

Frequency

60/50Hz+/-10%

Output

Voltage (AC Mode)

105-135VAC / 190-250VAC

Voltage (Inverter Mode)

120VAC / 220VAC ±5%

Capacity

500VA/300W

650VA/360W

800/480W

1000VA/600W

1200/720W

1500VA/880W

Frequency (Inverter Mode)

60/50Hz+/-0.5Hz

Transfer Time

2ms typical

Generator connection

Normal Working under the Generator

Waveform

modified-Sinewave

Protection

Spike & Surge Suppression

yes

Over/Under Volt.

Switch to Bat.O / Pwhen Mains over regulation range

Over load /short Circuit

Fuse & current limited for both Mains and Battery modes

Battery

Type

Lead-Acid maintenance-free

Dc Bus

12V7.0Ah

12V9.0Ah

12V7.0Ah

12V9.0Ah

Number

1 PC

1

2 PCS

Recharge time

8hours≥90%

Back up time(one PC)

8-15mins

10-18mins

15-25mins

20-30mins

20-30mins

25-45mins

Physical

Weight (KGs)

5

5.5

6

10.5

11

11.5

ShippingWt.

5.6

6

6.5

11

11.5

12

Product Dimensions (mm)

335*95*160

355*120*195

Packing Dimensions (mm)

395*360*230 mm/ 2 PCS in 1 Carton

435*395*275/ 2 PCS in 1 Carton

Soft ware

RS232 or USB optionWindows & NT

Auto save & shut down

Function

Cold start

UPS Start The Computer Even there Is no Main Power

Automatic Charge

Automatic Charge when UPS is off

Automatic Restart

Automatic Restart if main power coming within one hour

Voltage display

220v/230v Optionalfollowing the real capacity

Frequency

50HZ/60HZ Optioanl following the real

Beeping

During the battery mode ,the beeping optional

Efficiency

AC-AC

1

DC-AC

0.6

Acoustic

Noise level

≤45dB

Environmental

Temperature

-5-45 DegreeC

Humidity

20% to 90%

Power Outlets

No. and types

2SOCKETS

3 SOCKETS