●CPU control | |||
●With Stabilizer Function | |||
●Wide Input Voltage Range | |||
●Wide Input Frequency Range | |||
●High/Low Voltage Protection, Overload/Short Protection | |||
●Cool start computer even there isnt main power | |||
●Automatic recharge even UPS is off | |||
●Automatic restart | |||
●Beeping Alarm on Battery, Battery Low and Overload | |||
●Beeping Selection | |||
●Intelligent Battery Management | |||
●Intelligent LCD Display | |||
●Smart RS232& RJ11& USBOption | |||
●Compatibility with generators |
Overview |
Product | Requirements | Model 1 | Model 2 | Model 3 | Model 4 | Model 5 |
Power (VA) | PCT-500 | PCT-650 | PCT-1000 | PCT-1500 | PCT-2000 | |
Input | Voltage | 145-290VAC±5V | ||||
Frequency | 50Hz+/-10% | |||||
Output | Voltage (AC Mode) | 190-250VAC | ||||
Voltage (Inverter Mode) | 220VAC ±5% | |||||
Capacity | 500VA/300W | 650VA/360W | 1000VA/600W | 1500VA/880W | 2000VA/1200W | |
Frequency (Inverter Mode) | 50Hz+/-0.5Hz | |||||
Transfer Time | 2ms typical | |||||
Generator connection | Normal Working under the Generator | |||||
Waveform | modified-Sinewave | |||||
Protection | Spike & Surge Suppression | yes | ||||
Over/Under Volt. | Switch to Bat.O / Pwhen Mains over regulation range | |||||
Over load /short Circuit | Fuse & current linited for both Mains and Battery modes | |||||
Battery | Type | Lead-Acid miantenance-free | ||||
Dc Bus | 12V7.0Ah | 12V7.0Ah | 12V9.0Ah | 12V7.0Ah | ||
Number | 1 PC | 2 PCS | ||||
Recharge time | 8hours≥90% | |||||
Back up time(one PC) | 8-15mins | 10-18mins | 20-30mins | 25-45mins | 30-45mins | |
Physical | Weight (KGs) | 5 | 5.5 | 10.5 | 11.5 | 17 |
ShippingWt. | 5.6 | 6 | 11 | 12 | 18 | |
Product Dimensions (mm) | 335*95*160 | 355*120*195 | 410*145*215 | |||
Packing Dimensions (mm) | 435*395*275/ 2 PCS in 1 Carton | 435*395*275/ 2 PCS in 1 Carton | 495*250*335 | |||
Soft ware | RS232 or USB optionWindows & NT | Auto save & shut down | ||||
Function | Cold start | UPS Start The Computer Even there Is no Main Power | ||||
Automatic Charge | Automatic Charge when UPS is off | |||||
Automatic Restart | Automatic Restart if main power coming within one hour | |||||
Voltage display | 220v/230v Optionalfollowing the real capacity | |||||
Frequency | 50HZ/60HZ Optioanl following the real | |||||
Beeping | During the battery mode ,the beeping optional | |||||
Efficiency | AC-AC | 1 | ||||
DC-AC | 0.6 | |||||
Acoustic | Noise level | ≤45dB | ||||
Environmental | Temperature | -5-45 DegreeC | ||||
Humidity | 20% to 90% | |||||
Power Outlets | No. and types | 2SOCKETS | 3 SOCKETS | 4 SOCKETS |