    | ��High frequency and double conversion online UPS �� Single phase, Power Factor 0.8�� Fully digitized microprocessor control�� Wide input voltage range�� Advanced PFC technology�� Self-testing when UPS startup�� Advanced battery management�� Automatic battery charging in UPS off mode�� Lightning and surge protection�� Short circuit and overload protection�� Smart RS232 communication with monitoring software�� Battery voltage and load capacity display�� SNMP card optional�� LCD display and EPO��ECO Function optional�� N+X parallel design optional |  | 
| ITEM | MODEL | N-C6K | N-C6KS | N-C10K | N-C10KS | N-C15KS | N-C20KS | |
| Capacity | VA /  | 6KVA / 4.8KW | 10KVA / 8KW | 15KVA / 12KW | 20KVA / 14KW | |||
| Input | Normal voltage | 220VAC, L+N+G | ||||||
| Input Voltage range | 120V-275V | |||||||
| Frequency range | 50/60��10% | |||||||
| Input power factor | >0.99(220VAC,full R load) | |||||||
| Generator | Support generator input(Generator rating��2*UPS rating | |||||||
| Output | Voltage range | 220VAC+-1% | ||||||
| Frequency range | 48Hz/54Hz(AC mode), 50HzX(1��0.1��)(Battery mode) | |||||||
| Wave form  | Pure Sine Wave | |||||||
| Transfer Time | 0 ms | |||||||
| Distortion (Full Load) linear load | < 3% | |||||||
| distortion (Ful l Load) nonlinear load | < 5% | |||||||
| Overload capacity | 105%~125% ,1min then transfer to bypass and alarm. 125%~150% 30s then transfer to bypass and alarm,1min then cut off output. >150% ,0.5s then transfer to bypass and alarm. | |||||||
| Load peak ratio | 3:1(max) | |||||||
| Type | Maintenance free valve regulated lead acid (VRLA) battery | |||||||
| 192VDC | 192VDC | 192VDC | 192VDC | 192VDC | 192VDC | |||
| internal 16*7AH | External | internal 16*7AH | External | External | External | |||
| Around backup time (Full load) | 4Mins | up to external battery capacity | 3Mins | up to external battery capacity | ||||
| Around backup time (Half load) | 12Mins | 9mMins | up to external battery capacity | |||||
| Recharge time | 7 hours to 90%capacity  | up to external battery capacity | 7 hours to 90%capacity  | up to external battery capacity | ||||
| LED Display | LED | Load level / Battery level /  | ||||||
| Audible Alarm | Beeping every 4 seconds (re-settable) and every second when battery | |||||||
| Overload | Beeping twice every second | |||||||
| UPS Fault | Beeping Continuously | |||||||
| Bettery low/charger fault | Beeping every 1 second | |||||||
| Bypass mode | Beeping every 2 min | |||||||
| L/N inverse | Beeping every 2 min | |||||||
| Communications | RS-232 Interface | With monitoring software | ||||||
| Working Environment | Working temperature | -  | ||||||
| Humidity | 0-95% non-condensing | |||||||
| product dimension | WxDxH (mm) | 248*500*616 | 240*500*460 | 248*500*616 | 240*500*460 | 248*500*616 | 248*500*616 | |
| Package size | WxDxH (mm) | 700*385*851 | 595*390*578 | 700*385*851 | 595*390*578 | 700*385*851 | 700*385*851 | |
| Package weight | N.weight(Kg) | 57 | 18 | 67.5 | 20 | 35 | 35 | |
| Gross weight(Kg) | 71 | 23 | 77.5 | 27.5 | 45 | 45 | ||
| optional functions | ECO | optional | ||||||
| EPO | optional | |||||||
| LCD display (optional) | input / output VAC & HZ, Load Rate, | |||||||
| REMARK | C*k --- Standard Type, C*Ks(-N)---- Long Time Type | |||||||


  