Picture of SLP pure sine wave Line UPS

SLP pure sine wave Line UPS

SKU: FS00019485
Reproduction is welcome and allowed for free circulation only.
     
Main Features APPLICATION: pc,servers networks Data Processing;application of Telecommunications;process of control and of access;
equipment of security。
Technology line interactive with AVR
Design of high frequency
High/Low Voltage Protection
Overload/Short Protection
UPS Start up without battery
Cool start (0 to 100% load)
Spike & Surge Suppression
Automatic recharge even UPS is off
Audible Beeping Alarm
LED display
Frequency Selection Automatically
Intelligent Battery Management
USB, RS232,Dry Contact ,SNMP/WEB(optional), communication with software
Compatibility with generators
Battery Replacement Hot
2 in 1 dual format tower and rack
Protective fax / modem with 2 RJ11 /RJ45(Option) ,EPO(optional)
Scalable autonomy in using kits
Overview
Model SLP-750VA SLP-1K SLP-1.5K SLP-2K   SLP-3K
Capacity (VA/W) 750VA/500W 1000VA/700W 1.5000VA/1050W 2000VA/1340W   3000VA/2100W
1.INPUT
Input Voltage
Phase Single Phase With Ground
Nominal Input Voltages (Selectable) 110V 120V 127V 220V 230V 240V
Transfer Voltage Range VAC (+4%~-4%) Based on load percentage
Acceptable Input Voltage Range 0 - 160 Vac 0 - 300 VAC
Line low Threshold 88 96 102 176 184 192
Line low Comeback 93 101 107 186 194 202
Line boost Threshold 99 108 114 198 207 216
Line boost Comeback 103 112 120 206 215 225
Line buck Comeback 113 123 130 225 236 246
Line buck Threshold 116 127 135 233 243 254
Line high Comeback 127 139 147 254 266 278
Line high Threshold 132 144 152 264 276 288
Input Frequency Input frequency For 60 Hz units (auto selection ) Input frequency For 50 Hz units (auto selection )
Default frequency (cold start) 60HZ 50 Hz
Nominal Frequency 50 Hz/60 Hz 50 Hz/60 Hz
Transfer Frequency 60 Hz 50 Hz
Freq. Low Loss 55 ± 0.1 Hz 45 ± 0.1 Hz
Freq. Low Comeback 56 ± 0.1 Hz 46 ± 0.1 Hz
Freq. High Loss 65 ± 0.1 Hz 55 ± 0.1 Hz
Freq. High Comeback 64 ± 0.1 Hz 54 ± 0.1 Hz
Converter(Generator) Support
Freq. Low Loss 40.0 ± 0.2 Hz
Freq. Low Comeback 42.0 ± 0.2 Hz
Freq. High Loss 70.0 ± 0.2 Hz
Freq. High Comeback 68.0 ± 0.2 Hz
Input Power Factor
Input Power Factor ≥95%, Full RCD Load@ full PFC load and fully charged battery; boost and buck mode ≥ 92%.
Input Protection BREAKER +Software Protection
2.OUTPUT
1).On-Line Output
Output Waveform Sine wave, same as input
Output Frequency Range Same As Input Frequency
Output Voltage regulation 110V 120V 127 V 220V 230V 240V
Range (Outside of this range the units operates on Battery)
99~116 108~127 114 ~135 198~233 207~243 216~254
Boost Mode Voltage 114% of Vin
Buck Mode Voltage 88 % of Vin
Line Mode overload(SMPS Load)

110% -0%, +8%; fault after 3 minutes
Line Mode overload(SMPS load)
150% -0%, +10%; fault after 10 cycles minimum
2.)Output, Inverter / Battery Mode
Voltage Regulation ± 5% of nominal; +5% ,-10% after Low Battery Warning
Output Waveform Sine wave
Frequency Regulation ±50/60±0.1 Hz
Output Voltage Transient Response (Overshoot / Undershoot) (Battery mode with PFC type load)
0%-100%-0% Load; ±15 % max.
20%-100%-20% Load; ±8% max.
Transient Recovery To nominal voltage within 30ms.
Output Voltage THD At Low Battery Warning: 100% PFC Load < 5%THD; 100% NLL < 10% THD At Battery Cut Off: 100% PFC load < 10% THD; 100% NLL <15% THD
3.Efficiency >85 % at 100% NLL
Short Circuit Protection Active current limit; Shutoff within 300 ms.
Battery Mode overload (SMPS load) ≥ 110 % ± 6 %; fault after 30 seconds minimum
≥ 120 % ± 6 %; fault after 5 cycles minimum
DC Component in the Output voltage 10sec average < 0.1% of rms value of output voltage
Load Take On 150 msec; no load to 100 % RCD (8 mF/W) load to within 90 % of nominal output voltag < 150 msec; no load to 100 % RCD (2 mF/W ) load to within 90 % of nominal output voltage
Transfer Time 2-4 msec typical, 6 msec max.
4.Short Circuit Protection            
Line Mode/ Battery Mode Cut Off Output Within 300ms Then Fault
5.Battery            
Model CL-750VA CL-1K CL-1.5K CL-2K   CL-3K
Capacity (VA/W) 750VA/500W 1000VA/700W 1.5000VA/1050W 2000VA/1340W   3000VA/2100W
OUTPUT 24VDC 48VDC 96VDC
Type/Capacity CSB 12V/7AH CSB 12V/9AH CSB 12V7AH CSB 12V9AH   CSB 12V/4.5AH
Battery Quantity 2PCS 2PCS 4PCS 4PCS   8PCS
Backup Time 5minutes 5minutes 5minutes 5minutes   5minutes
(With full RCD load) Alarm 2 minutes before it Shutdown Alarm 2 minutes before it Shutdown Alarm 2 minutes before it Shutdown Alarm 2 minutes before it Shutdown   Alarm 2 minutes before it Shutdown
Battery Protection
Low Alarm Voltage (VDC) 10.5±0.5V
Low Alarm Comeback Voltage (VDC) 11±0.5V
Auto Shutdown Voltage (VDC) 10±0.5V
Battery Protection 80A/Fuse 50A/Fuse
Battery Leakage 200uA
Battery Test
Battery Fault Transfer To Line Mode Immediately then alarm
Default time Every 30 days
6.Charger            
Fast Charge Voltage 28.6~29.2vdc 28.6~29.2vdc 57.2~58.4vdc 57.2~58.4vdc   114.4~117.2vdc
Float Charge Voltage 26.8~27.6vdc 26.8~27.6vdc 53.6~55.2vdc 53.6~55.2vdc   107.2~111vdc
Charging Current 1.0A 1.0A 3.0A 3.0A   3.0A
Charge Time Internal battery modules will recharge less than 3 hours to 90%
7.Temperature-compensated Yes
8.Controls and audio alarm            
Control            
Alarm Silence Yes, In Battery Mode
DC Power Start Yes, In Battery Mode
Auto Restart Function Yes, In Line Mode
Cooling Force Air Cooling
Audio Alarm            
Battery Mode Beep/4 Sec
Battery Low Beep/1 Sec
Battery Replacement Beep/1 Sec  
UPS Fault Continuous
Over Load Beep/1 Sec
9. USER INTERFACE
           
Network Transient Protection RJ45
Indicator LCD/LED Indicator
Communication            
SNMP Card Webpower (Optional)
USB Standard (Optional)
RS232 Standard (DB9)
EPO Function Short circuit the EPO, the UPS will shutdown immediately
Dry Contact AS 400 card (optional) & DB9
10. OPERATION ENVIRONMENT            
Acoustic Noise ≤50dB
Working Temperature 0 ℃ to 40℃
(Long term use at ambient higher than 25°C reduces battery life)
Transit Temperature -20°C to +55 °C
Storage Temperature -20°C to +55 °C
Humidity <95%
Altitudes            
Operating Altitude 0-1500 meters@ 0-40°C/1501-3,000 meters @ 0-35 °C
Non-Operating Altitude 0 to 15,000 meters
Products Size(mm) 217*86.5*413.5 217*86.5*413.5 217*86.5*413.5 217*86.5*413.5   438*86.2*582
Products Weight(KG) 15 16 23 23   34.1