General(HBR1 series motor power supply)
The soft starting technology of AC squirrel-cage motor has been applied for many years in the developed country, it has successfully solved the following problems during AC motor starting: supply voltage quality affected by large starting
current, high power consumption of power supply circuit, impact on mechanical equipment. HBR1 series full digital soft starter adopts advanced 16
digits single-chip microcomputer as the core to controlthyristor of high power, it has obvious functions like soft starting, current-limit starting, full voltage
starting, double-ramp starting, soft starting and so on, besides, it has over current protection, overload protection, phase failure protection,etc, its all parameterscan be set automatically according to loads . Its output voltage rises as per setting regulation, to make the controlled motor get full voltage from setting value. After the starter finishes starting, it will bypass the thyristor,
and let AC contactor begin to work. HBR1 series soft starter covering 5.5~500kw, is widely applied to various fields like metallurgy, petrol, chemical
industry, construction, cement, mining, environmental protection and so on, it is the best new generation productinstead of star delta starter, reactor starter and auto step-down starter.
Features(HBR1 series motor power supply)
With 16-digit single-chip microcomputer, full digital automatic control.
Starting torque, current, voltage and time can be set flexibly according to different loads.
Provide motor with smooth and gradual starting course, reduce the impact on power grid from starting current
The starting current can be adjusted according to loads.
The character of soft stopping is helpful for prolonging the life of electric contact and satisfying the machinery
requirements on different occasions.
With over current protection, overload protection,phase failure protection and so on, it can preventthe motor and equipment being damaged effectively.
External control interface provided is convenient foruser to realize interlocking or self-control.
Delay the input of starting control and soft stoppingcontrol. Starting delay relay outputs, fault relayoutputs.
Stop and operate soft stopping freely, the time ofsoft stopping is adjustable.
Novel product structure, small volume, reliableperformance, convenience for installation andoperation.
The isolation of double power supply is good forprotecting control part against interference ofkinds of strong electricity.
Pump (HBR1 series motor power supply)

No water pressure fluctuation in the pipe: the soft starter can solve the problem that there is some fluctuation of
water pressure in the pipe when water pump motor starts or stops, its starting current can be down to 1/3~1/4
time. Besides, the current peak value can be eliminated during star delta starting.

Fan (HBR1 series motor power supply)

The belt can't skid: soft starter can prevent the belt skidding and can reduce the stress of bearing when the fan
starts.

Air compressor,centerifuge,agitator(HBR1 series motor power supply)

Air compressor, centrifuge, agitator
For reducing stress of machines: the soft starter can reduce the stress on gear box and driving belt when
compressor, centrifuge and agitator starts.

Conveying belt(HBR1 series motor power supply)

Conveying belt
The soft starter can take effect on preventing product falling down or being damaged when the conveying belt
starts or stops, and it also can reduce the belt abrasion and stress on the gear box for skidding of belt when
starting, its hydraulic coupling can take the place of direct coupling.

Common performanch(HBR1 series motor power supply)

Common performance
For reducing starting current: over high starting current will result in the falling of power grid voltage, subsequently,
it causes the interference to the load of weak power grid. Soft starter can solve above problem, the area of cable
and the size of fuse will get small correspondingly, so the installation cost can be reduced. Reduce starting current
can be good for reducing electricity expense.

Description about control terminal(HBR1 series motor power supply)
Terminal mark terminal name Descrition
CMContact input common terminal Common terminal of contact input signal
RUNStarting input terminal Motor begins running when RUN-CM switches on
STOPStopping input terminal Motor begins stopping when STOP-CM breaks
OE1,2,3External fault input terminal Motor stops immediately when OE-CM breaks
JRA、B、CRunning output signal JRA-JRB is the NO contact,JRB-JRC is the NC contact
JMA、B、CAlarming output signal JMA-JMB is the NO contact,JMB-JMC is the NC contact
General data(HBR1 series motor power supply)

Time of stopping falling: 0~60S
Limit of starting current: 50~400%
Time of starting to rise: 0~100s
Overload current: 50~300%
Rated power supply: three-phase 380V
General motor:7.5~500KW
Environment temp.: -10℃~55℃
Initial voltage: 40-380V
Initial time: 0~20S

Spec.&modelPower(KW)Over size(mm) Installation size (mm) Weight(kg)
ABCDEF
HBR1-S-17KW1732823422428830518417
HBR1-S-22KW2232823422428830518417
HBR1-S-30KW3032823422428830518417
HBR1-S-37KW3741027822337039015017
HBR1-S-45KW4541027822337039015017
HBR1-S-55KW5541027822337039015017
HBR1-S-90KW9019576705801900460570110
HBR1-S-115KW11519576705801900460570110
HBR1-S-130KW13219576705801900460570110
HBR1-S-160KW16019576705801900460570110
HBR1-S-200KW20019576705801900460570110
HBR1-S-250KW25019608006601900550645150
HBR1-S-320KW32019608006601900550645150
HBR1-S-400KW400226011008002200800700200
HBR1-S-500KW500226011008002200800700200

Spec.&modelPower(KW)Over size(mm) Installation size (mm) Weight(kg)
ABCDEF
HBR1-S-17KW172552862152533052568
HBR1-S-22KW222552862152533052568
HBR1-S-30KW302552862152533052568
HBR1-S-37KW3733039023533030036014.5
HBR1-S-45KW4533039023533030036014.5
HBR1-S-55KW5533039023533030036014.5
HBR1-S-90KW9054043025048051038537
HBR1-S-115KW11554043025048051038537
HBR1-S-130KW1321957670560190046057037
HBR1-S-160KW1601957670560190046057037
HBR1-S-200KW2001957670560190046057037
HBR1-S-250KW2501957670560190046057037
HBR1-S-320KW3201957670560190046057037
HBR1-S-400KW4001957670560190046057037