��High frequency and double conversion online UPS �� Single phase, Power Factor 0.8�� Fully digitized microprocessor control�� Wide input voltage range�� Advanced PFC technology�� Self-testing when UPS startup�� Advanced battery management�� Automatic battery charging in UPS off mode�� Lightning and surge protection�� Short circuit and overload protection�� Smart RS232 communication with monitoring software�� Battery voltage and load capacity display�� SNMP card optional�� LCD display and EPO��ECO Function optional�� N+X parallel design optional |
ITEM | MODEL | N-C6K | N-C6KS | N-C10K | N-C10KS | N-C15KS | N-C20KS | |
Capacity | VA / | 6KVA / 4.8KW | 10KVA / 8KW | 15KVA / 12KW | 20KVA / 14KW | |||
Input | Normal voltage | 220VAC, L+N+G | ||||||
Input Voltage range | 120V-275V | |||||||
Frequency range | 50/60��10% | |||||||
Input power factor | >0.99(220VAC,full R load) | |||||||
Generator | Support generator input(Generator rating��2*UPS rating | |||||||
Output | Voltage range | 220VAC+-1% | ||||||
Frequency range | 48Hz/54Hz(AC mode), 50HzX(1��0.1��)(Battery mode) | |||||||
Wave form | Pure Sine Wave | |||||||
Transfer Time | 0 ms | |||||||
Distortion (Full Load) linear load | < 3% | |||||||
distortion (Ful l Load) nonlinear load | < 5% | |||||||
Overload capacity | 105%~125% ,1min then transfer to bypass and alarm. 125%~150% 30s then transfer to bypass and alarm,1min then cut off output. >150% ,0.5s then transfer to bypass and alarm. | |||||||
Load peak ratio | 3:1(max) | |||||||
Type | Maintenance free valve regulated lead acid (VRLA) battery | |||||||
192VDC | 192VDC | 192VDC | 192VDC | 192VDC | 192VDC | |||
internal 16*7AH | External | internal 16*7AH | External | External | External | |||
Around backup time (Full load) | 4Mins | up to external battery capacity | 3Mins | up to external battery capacity | ||||
Around backup time (Half load) | 12Mins | 9mMins | up to external battery capacity | |||||
Recharge time | 7 hours to 90%capacity | up to external battery capacity | 7 hours to 90%capacity | up to external battery capacity | ||||
LED Display | LED | Load level / Battery level / | ||||||
Audible Alarm | Beeping every 4 seconds (re-settable) and every second when battery | |||||||
Overload | Beeping twice every second | |||||||
UPS Fault | Beeping Continuously | |||||||
Bettery low/charger fault | Beeping every 1 second | |||||||
Bypass mode | Beeping every 2 min | |||||||
L/N inverse | Beeping every 2 min | |||||||
Communications | RS-232 Interface | With monitoring software | ||||||
Working Environment | Working temperature | - | ||||||
Humidity | 0-95% non-condensing | |||||||
product dimension | WxDxH (mm) | 248*500*616 | 240*500*460 | 248*500*616 | 240*500*460 | 248*500*616 | 248*500*616 | |
Package size | WxDxH (mm) | 700*385*851 | 595*390*578 | 700*385*851 | 595*390*578 | 700*385*851 | 700*385*851 | |
Package weight | N.weight(Kg) | 57 | 18 | 67.5 | 20 | 35 | 35 | |
Gross weight(Kg) | 71 | 23 | 77.5 | 27.5 | 45 | 45 | ||
optional functions | ECO | optional | ||||||
EPO | optional | |||||||
LCD display (optional) | input / output VAC & HZ, Load Rate, | |||||||
REMARK | C*k --- Standard Type, C*Ks(-N)---- Long Time Type |